Elliptically polarized light could cause large errors in superresolution microscopy

Nov. 1, 2018
Spin-orbit coupling of light in the emission of elliptically polarized emitters can cause wavelength-scale positioning errors.

Scientists at the Austrian Academy of Sciences (Vienna, Austria), TU Wien (also in Vienna), and the University of Innsbruck (Innsbruck, Austria) have demonstrated that elliptically polarized light can produce measurement errors in the optical position estimation of objects (for example, when using various forms of microscopy) of up to several hundred nanometers. The error-inducing wave effect is attributed to spin-orbit coupling of light in the emission of elliptically polarized emitters. The work could have consequences for optical microscopy and optical astronomy.

With modern superresolution optical imaging techniques, the position of objects can be measured with a precision that reaches a few nanometers. These techniques are used in the laboratory, for example, to determine the position of atoms in quantum experiments. “The elliptical polarization causes the wavefronts of the light to have a spiral shape and to hit the imaging optics at a slight angle,” says Yves Colombe, one of the Innsbruck researchers. “This leads to the impression that the source of the light is somewhat off its actual position.” The effect could be relevant, for example, in biomedical research, where luminous proteins or nanoparticles are used as markers to determine biological structures. This now-proven effect would possibly lead to a distorted image of the actual structures.

At Innsbruck, physicists determined, through single-photon emission, the position of a single barium atom trapped in an ion trap. Physicists at Vienna determined the position of a small gold sphere, about 100 nm in size, by analyzing its scattered light. In both cases, there was a difference between the observed and the actual position of the particle. “The deviation is on the order of the wavelength of the light and it can add up to a considerable measurement error in many applications,” says Stefan Walser, one of the TU Wien researchers. “Superresolution light microscopy, for example, has already penetrated far into the nanometer range, whereas this effect can lead to errors of several 100 nm.” The scientists believe it is very likely that this fundamental systematic error will play a role in superresolution microscopy applications, but this has yet to be proven in separate studies. Reference: G. Araneda et al., Nat. Phys. (2018); doi:10.1038/s41567-018-0301-y.

About the Author

John Wallace | Senior Technical Editor (1998-2022)

John Wallace was with Laser Focus World for nearly 25 years, retiring in late June 2022. He obtained a bachelor's degree in mechanical engineering and physics at Rutgers University and a master's in optical engineering at the University of Rochester. Before becoming an editor, John worked as an engineer at RCA, Exxon, Eastman Kodak, and GCA Corporation.

Sponsored Recommendations

What are Notch Filters?

Feb. 27, 2025
Notch filters are ideal for applications that require nearly complete rejection of a laser line while passing as much non-laser light as possible.

Using Optical Filters to Optimize Illumination in Fluorescence and Raman Systems

Feb. 27, 2025
Discover how Semrock products can help you get the most out of your fluorescence and Raman excitation designs, regardless of light source.

Melles Griot Optical Systems and Semrock Optical Filters for Spatial Biology

Feb. 26, 2025
Discover why a robust, high-throughput fluorescence imaging system with Semrock optical filters is key for Spatial Biology.

Understanding Practical Uses and Optimization Techniques for Fluorescence Optical Filters

Feb. 26, 2025
Learn about optical fluorescence and which optical filters to include in your instrument set up. See more with Semrock filter sets.

Voice your opinion!

To join the conversation, and become an exclusive member of Laser Focus World, create an account today!