Lens developed for hard x-ray nanoprobe beamline achieves 11 nm focal spot

Feb. 26, 2014
Upton, NY--At the National Synchrotron Light Source II (NSLS-II) now under construction at Brookhaven National Laboratory (BNL), 12 keV x-rays produced by the Hard X-ray Nanoprobe beamline (HXN) have now been focused down to an 11 nm spot size.

Upton, NY--At the National Synchrotron Light Source II (NSLS-II) now under construction at Brookhaven National Laboratory (BNL), 12 keV x-rays produced by the Hard X-ray Nanoprobe beamline (HXN) have now been focused down to an 11 nm spot size.1 The BNL researchers used a novel x-ray optic called a multilayer Laue lens (MLL), which consists of nested approximately cylindrical layers that focus hard x-rays via grazing incidence.

The researchers analyzed their MLL's focusing performance using a technique known as ptychography. "With ptychography, we can visualize how the x-rays are traveling from the lens to the focus and to an arbitrary point in the optical path. Therefore, we do not have to use conventional knife-edge scans to quantify lens aberrations," says Xiaojing Huang, one of the researchers. The ptychography analysis quantified the lens aberrations at a 0.3 wave period, very close to a quarter wave period. This represents a rigorous threshold value for "diffraction-limited" focusing.

The NSLS-II will enable scientists to image structures at ever-smaller spatial scales. HXN's long-range goal is to achieve a resolution of 1 nm. Hard x-rays exhibit excellent structural, elemental and chemical sensitivity and are particularly suited for in-situ studies that are challenging for electrons.

The Brookhaven-fabricated MLL has a 43-micron aperture (the largest yet reported MLL size). It accepts substantially more x-rays than earlier MLLs and offers a significantly larger working distance, needed for in-situ experiments. It also contains a total of 6,510 layers, with thicknesses ranging from 4 to 21 nm.

Source: http://www.bnl.gov/newsroom/news.php?a=24676

REFERENCE:

1. Xiaojing Huang et al., Scientific Reports 3, Article number: 3562. DOI: 10.1038/srep03562

About the Author

John Wallace | Senior Technical Editor (1998-2022)

John Wallace was with Laser Focus World for nearly 25 years, retiring in late June 2022. He obtained a bachelor's degree in mechanical engineering and physics at Rutgers University and a master's in optical engineering at the University of Rochester. Before becoming an editor, John worked as an engineer at RCA, Exxon, Eastman Kodak, and GCA Corporation.

Sponsored Recommendations

Melles Griot Optical Systems and Semrock Optical Filters for Spatial Biology

Feb. 26, 2025
Discover why a robust, high-throughput fluorescence imaging system with Semrock optical filters is key for Spatial Biology.

Working with Optical Density

Feb. 26, 2025
Optical Density, or OD, is a convenient tool used to describe the transmission of light through a highly blocking optical filter.

Finding the Right Dichroic Beamsplitter

Feb. 26, 2025
Unsure how to select the right dichroic beamsplitter? Explore our selection guide for our wide variety of 45º dichroic beamsplitters.

Measurement of Optical Filter Spectra

Feb. 26, 2025
Learn about the limitations of standard metrology techniques and how Semrock utilizes different measurement approaches to evaluate filter spectra.

Voice your opinion!

To join the conversation, and become an exclusive member of Laser Focus World, create an account today!