December 17, 2007, Enschede, The Netherlands--The perfusion of a burn injury can now be rapidly determined by using a new ultrafast-laser-based technique developed by scientists at the University of Twente.

December 17, 2007, Enschede, The Netherlands--The perfusion of a burn injury can now rapidly be determined by using a new ultrafast-laser-based technique developed by scientists at the University of Twente. Using the perfusion image made by a laser and an ultrafast camera, doctors will be able to determine whether a burn needs surgery.

The new measuring device, developed under supervision of Dr. Wiendelt Steenbergen of the Biophysical Engineering group, has been successfully tested at the hospital Martini Ziekenhuis in Groningen. The tests show that the system is capable of measuring differences in perfusion in burn wounds; patients and medical staff are positive about the high speed of the system and the quality of the images.

A burn that shows good perfusion, has a better chance of healing by itself: no surgery is needed. In many cases, the visual inspection is not sufficient to take a decision on the necessity of surgery. This can lead to unnecessary surgery or, on the other hand, to unwanted delays when surgery is the best option.

Compared to current perfusion measurements, the new technique is much faster. Scanning techniques take minutes of time for some square centimeters of skin, during which time the patient is not allowed to move. The new technique will be capable of imaging an entire surface of ten by ten centimeter in a fraction of a second.

In order to reach this high speed, the entire surface is lit at once using a wide laser beam. A high speed camera, capable of taking 27,000 shots/sec, takes images of the tissue. Whenever laser light is scattered by moving rood blood cells, this is visible in the intensity of the pixels; due to the Doppler effect, a color shift will be visible. From the resulting "movie" of the tissue, a perfusion image can be made.

Apart from this promising application in determing perfusion in burn injuries, Wiendelt Steenbergen predicts other applications, for example in evaluating the uptake of medication through the skin, or in testing allergic reactions. In evaluating diabetic micro circulation problems, the new technique could be an attractively fast alternative to current approaches as well.

Current market leader in Laser-Doppler equipment for perfusion imaging, Perimed AB from Sweden, has shown interest in the new technique. The Swedish company has signed a contract with Dutch Technology Foundation STW, for acquiring the patent on the technique. STW finances Steenbergen's work.

The research has been done within the Biophysical Engineering Group of the University of Twente, which is part of the BMTI Institute for Biomedical Technology.

Sponsored Recommendations

Brain Computer Interface (BCI) electrode manufacturing

Jan. 31, 2025
Learn how an industry-leading Brain Computer Interface Electrode (BCI) manufacturer used precision laser micromachining to produce high-density neural microelectrode arrays.

Electro-Optic Sensor and System Performance Verification with Motion Systems

Jan. 31, 2025
To learn how to use motion control equipment for electro-optic sensor testing, click here to read our whitepaper!

How nanopositioning helped achieve fusion ignition

Jan. 31, 2025
In December 2022, the Lawrence Livermore National Laboratory's National Ignition Facility (NIF) achieved fusion ignition. Learn how Aerotech nanopositioning contributed to this...

Nanometer Scale Industrial Automation for Optical Device Manufacturing

Jan. 31, 2025
In optical device manufacturing, choosing automation technologies at the R&D level that are also suitable for production environments is critical to bringing new devices to market...

Voice your opinion!

To join the conversation, and become an exclusive member of Laser Focus World, create an account today!